Search results for "optic fibre"

showing 3 items of 3 documents

Monitoring the Etching Process in LPFGs towards Development of Highly Sensitive Sensors

2017

Trabajo presentado en la Eurosensors 2017 Conference. París, 3–6 de septiembre de 2017. In this work, the monitoring of the etching process up to a diameter of 30 µm of two LPFG structures has been compared, one of them had initially 125 µm, whereas the second one had 80 µm. By tracking the wavelength shift of the resonance bands during the etching process it is possible to check the quality of etching process (the 80 µm fibre performs better than de 125 µm fibre), and to stop for a specific cladding mode coupling, which permits to obtain an improved sensitivity compared to the initial structure. This work was supported by the Spanish Agencia Estatal de Investigación (AEI) and Fondo Europeo…

CouplingMaterials sciencerefractive indexbusiness.industryProcess (computing)Refractive indexResonancelcsh:ALong-period fiber gratingLong period fiber gratingCladding modeoptic fibre sensorOpticsEtchingEtching (microfabrication)etchingSensitivity (control systems)lcsh:General WorksbusinessOptic fibre sensorRefractive indexlong period fiber gratingProceedings
researchProduct

In vivo muscle mechanics during normal locomotion is dependent on movement amplitude and contraction intensity

2001

The effects of movement amplitude and contraction intensity on triceps surae and quadriceps femoris muscle function were studied during repetitive hopping. In vivo forces from Achilles and patellar tendons were recorded with the optic fibre technique from eight volunteers. The performances were filmed (200 Hz) to determine changes in muscle-tendon unit length and velocity. When hopping with a small amplitude (23° knee flexion during the ground contact phase), the Achilles tendon was primarily loaded whereas patellar tendon forces were greater in large-amplitude hopping (56° knee flexion). In spite of the different magnitudes of stretch in the quadriceps femoris muscle, the stretching veloci…

musculoskeletal diseaseshoppingmuscle activiryeconomyoptic fibretendon forcemusculoskeletal system
researchProduct

In vivo triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump

2000

An optic fibre method was used to measure in humans in vivo Achilles (ATF) and patellar tendon forces (PTF) during submaximal squat jumps (SJ) and counter movement jumps (CMJ). Normal two-legged jumps on a force plate and one-legged jumps on a sledge apparatus were made by four volunteers. Kinetics, kinematics, and muscle activity from seven muscles were recorded. The loading patterns of the tendomuscular system differed among the jumping conditions, but were similar when the jumping height was varied. Peak PTF were greater than ATF in each condition. In contrast to earlier simulation studies it was observed that tendomuscular force could continue to increase during the shortening of muscle…

poweroptic fibretendon forcemuscle-tendon interactionmuscle mechanics
researchProduct